Category | Description | Parameter |
package | External dimensions of export wooden cases | 830mm×390mm×480mm |
net weight | 16.5KG | |
Gross weight | 30KG | |
size | overall machine size | See picture |
heating length | <130mm | |
heating diameter | <25mm | |
Heating pipe | heating pipe name | Infrared radiation tube |
heating pipe power | 500W*4=2000W | |
Power Supply | power demand | AC 220V ±10% 50HZ |
whole machine power | 2.3KW | |
safe | security level | PE |




FAULT | REASON | PROCESSING METHOD |
The cooling fan does not work | The device is not powered | Connection power |
“Power switch” OFF | Power ON | |
Damage of blower | Replacement blower | |
Heater not working | “Power switch” OFF | Power ON |
The heating pipe is damaged | Replace the heating pipe | |
Heater circuit problem | Check the line | |
Footswitch damaged | Replace the foot switch | |
Controller damaged | Replace the controller |
Serial No | Maintenance content | Inspection cycle |
1 | Check the heater cooling fan for operation | Every day |
2 | Check whether the current is between 8.5A and 9.5A when the equipment is running, or whether all heating tubes are heated | 100 hours of operation |
3 | Press the leakage protector test button to check whether the circuit breaker operates normally | 100 hours of operation |